Revitalize your Asset 422 with a fresh battery to ensure uninterrupted tracking. This guide simplifies the battery replacement process, catering to both experienced users and those new to GPS trackers. Follow these steps to replace your Asset 422's battery efficiently.


Necessary Tools

  • Philips #00 screwdriver

  • Flat prying tool


Step-by-Step Instructions

  1. Open the Enclosure:

    • Locate the four corner screws on the back of the device.

    • Remove these screws with the Philips #00 screwdriver.

    • Lift the front plate off to reveal the PCB (Printed Circuit Board).

  2. Detach the PCB (Printed Circuit Board)

    • Unscrew the two screws holding the PCB in place, located at the top-right and bottom-left corners.

    • Carefully lift the PCB using the flat prying tool, mindful of the battery wires attached to the back.

  3. Extract the Old Battery:

    • Disconnect the battery's connector from the board.

    • Pry the battery-free, noting that adhesive may secure it to the enclosure.

  4. Install the New Battery:

    • Position the new battery onto the adhesive area in the enclosure.

    • Connect the new battery's wires to the PCB.

    • Place the PCB back over the new battery, aligning it correctly.

    • Re-screw the PCB to the enclosure using the screws set aside earlier.

  5. Reset Battery Indicator:

    • On the mobile or web platform, go to your commands list.

    • Execute the "Reset Battery Percentage to 100%" command.

  6. Allow Time for the Reset:

    • It may take up to 24 hours for the reset to reflect.

    • Ensure the tracker is powered on and has a strong signal to receive the command.


💡Tip

When replacing your Asset 422's battery, ensure all tools are prepared and handle the PCB with care to avoid damage. A clean workspace aids in keeping track of small components. After installation, remember to reset the battery indicator to accurately reflect the new battery's charge level.


What's Next?

Need more help? Get support from our team by contacting us through our Support Center at https://logistimatics.com/contact/.

You can also email us at hello@logistimatics.com.

Our dedicated support team is available to assist you from Monday to Friday, 9 AM to 5 PM Eastern Time.

Did this answer your question?